Docs
Steps

Alarm panel

Armed, disarmed, triggered…

When step — What starts the flow. Step type when-alarm.

How it works

Starts the flow on alarm panel events: armed, armed away or stay, disarmed, arming, entry delay, triggered, or a zone opening while armed. Pick the intrusion, smoke or CO panel.

Example

Alarm panel (armed away) → Control devices (all lights off) → Control devices (thermostat eco)

Arming away also sets the house to away mode.

Options

OptionKeyKindRequiredNotes
Panelpanelselectnooptions: intrusion, smoke, co
Eventeventselectyesoptions: armed, armed-away, armed-stay, disarmed, arming, pending, triggered, zone-opened
Only these sensors (empty = any zone sensor)zoneEntityIdsentitiesnodomains: binary_sensor, cover, lock; shown when event is zone-opened
Also when the sensor is bypassedincludeBypassedbooleannoshown when event is zone-opened

Exits

One exit. Triggers have no incoming connection.

Wire format

What the step stores in the flow definition's data bag (JSON schema).

Generated from docs-bundle v0.1.0, novon-platform 9ce3486c (2026-10-09).

On this page